ICS/OT

ICS Patch Tuesday: Security Advisories Released by CISA, Schneider, Siemens, Rockwell

CISA, Schneider Electric, Siemens, and Rockwell Automation have released November 2024 Patch Tuesday security advisories.

ICS Patch Tuesday

Siemens, Schneider Electric, CISA, and Rockwell Automation have released November 2024 Patch Tuesday security advisories.

Siemens has published a dozen new advisories. Based on severity score, the most important vulnerability is a critical deserialization issue in TeleControl Server Basic, which can allow an unauthenticated attacker to execute arbitrary code on the device.

In Sinec INS, Siemens patched roughly 60 vulnerabilities, including critical issues. Many of them impact third-party components used by the product. In Sinec NMS and Scalance M-800, the company addressed over a dozen flaws in each product, many of them impacting third-party components.

High-severity issues — one in each product — were addressed by Siemens in Engineering Platforms (code execution), OZW Web Servers (stored XSS), Spectrum Power 7 (local privilege escalation), Siport (privilege escalation), and Simatic CP 1543-1 (unauthorized file system access). 

Siemens also informed customers that Solid Edge is affected by several flaws that can be exploited for code execution or DoS attacks by getting the targeted user to open a specially crafted file.

Medium-severity issues have been addressed by the company in Mendix Runtime (bypass account lockout measures) and Ruggedcom Crossbow Station Access Controller (code execution, DoS).

Advertisement. Scroll to continue reading.

Schneider Electric has published four new advisories. One of them describes a critical EcoStruxure IT Gateway vulnerability that could allow an attacker to take control of the system and obtain sensitive information.

In PowerLogic PM5300 series power meters the industrial giant patched a high-severity DoS issue. 

In Modicon M340, Momentum and MC80 controllers, the company resolved five critical and high-severity issues that can be exploited in man-in-the-middle attacks to cause a DoS condition or execute arbitrary code.

Read: Siemens and Rockwell Tackle Industrial Cybersecurity, but Face Customer Hesitation

CISA has published three new advisories. One covers three critical vulnerabilities in the Subnet PowerSystem Center OT device management platform.

The second advisory describes two vulnerabilities in Hitachi Energy TRO600 radios that could be exploited for command execution with root privileges, and to obtain valuable configuration information.

The third advisory covers a high-severity remote code execution vulnerability in Rockwell Automation’s FactoryTalk View ME.

Rockwell Automation published its own Patch Tuesday advisory for this flaw, along with a second advisory describing one critical and two high-severity issues in FactoryTalk Updater. 

The FactoryTalk Updater vulnerabilities include an authentication bypass issue that allows an attacker to impersonate a user, a remote code execution bug that requires high permissions, and a local privilege escalation flaw.  

Related: ICS Patch Tuesday: Advisories Published by Siemens, Schneider, Phoenix Contact, CERT@VDE

Related: ICS Patch Tuesday: Advisories Published by Siemens, Schneider, ABB, CISA

Related Content

ICS/OT

Independently judged and sponsor-neutral, the new awards program honors the people, organizations, and technologies delivering proven impact in industrial cybersecurity; winners to be announced...

Artificial Intelligence

(Video) Artificial intelligence is transforming cybersecurity, but are governance, compliance, and security practices evolving fast enough to keep up?

ICS/OT

Legacy systems, safety concerns, and critical infrastructure risks make OT vulnerability disclosure one of cybersecurity's most challenging balancing acts.

ICS/OT

The industrial giants fixed dozens of vulnerabilities across their ICS products, with advisories also released by CISA and VDE CERT.

ICS/OT

CISA has published an advisory to inform organizations about three vulnerabilities found by a researcher in Daktronics controllers.

ICS/OT

CISA has added the remote code execution flaw CVE-2026-12569 to its Known Exploited Vulnerabilities catalog.

ICS/OT

The exploited flaw, CVE-2025-67038, is one of the vulnerabilities disclosed in April as part of the BRIDGE:BREAK research project.

ICS/OT

The 2026 Industrial Control Systems (ICS) Cybersecurity Conference takes place October 6-8, 2026, at the W Nashville.