An update released by Trihedral for its VTScada product patches several vulnerabilities, including high severity weaknesses that can be exploited even by less skilled hackers.

<p><strong><span><span>An update released by Trihedral for its VTScada product patches several vulnerabilities, including high severity weaknesses that can be exploited even by less skilled hackers.</span></span></strong></p>

An update released by Trihedral for its VTScada product patches several vulnerabilities, including high severity weaknesses that can be exploited even by less skilled hackers.

VTScada, Trihedral’s flagship product, is a software suite designed for creating human-machine interfaces (HMI) for supervisory control and data acquisition (SCADA) systems. The product is used in various industries, mainly in North America and Europe.

Security researcher Karn Ganeshen discovered several vulnerabilities affecting VTScada versions prior to 11.2.26. The expert told SecurityWeek that a Shodan search showed a few systems running VTScada accessible from the Internet, but he believes there are more vulnerable instances that are exposed to attacks.

One of the flaws, tracked as CVE-2017-6043 and assigned a CVSS score of 7.5, is a denial-of-service (DoS) issue that exists due to the VTScada client’s failure to limit resource usage.

In an advisory published on his website, Ganeshen said an attacker with a non-privileged account can cause excessive CPU and RAM usage by submitting a large payload (up to roughly 80,000 characters) in the username field of the login window.

“Where a full-blown application (or multiple applications in production scenario) is deployed, i.e. with an operational/functional configuration, memory/CPU usage is notably higher than that of a test, blank application,” the expert said. “Repeatedly submitting such a large username input rapidly consumes available server memory resources leading to resource exhaustion. This forces a system reboot eventually.”

Another high severity flaw found by the researcher in VTScada is CVE-2017-6045, an information disclosure issue that exposes potentially sensitive configuration data to unauthenticated attackers.

Ganeshen also informed Trihedral of several cross-site scripting (XSS) vulnerabilities that can be exploited to execute arbitrary JavaScript code in the targeted user’s browser. These security holes are considered medium severity and they are tracked as CVE-2017-6053.

Advertisement. Scroll to continue reading.

The flaws have been addressed by Trihedral with the release of VTScada 11.2.26. The researcher has confirmed that the resource exhaustion vulnerability has been properly patched.

In a brief statement published on Wednesday on its website, Trihedral pointed out that the vulnerabilities only affect “systems with unsecured internet connections with VTScada internet access enabled.” The company has advised customers to secure their connection and update the product to the latest version.

Ganeshen told SecurityWeek that he submitted two other VTScada vulnerability reports, which should soon be published by ICS-CERT.

Related: Learn More at SecurityWeek’s ICS Cyber Security Conference

Related: Trihedral Patches Flaws in SCADA Software

Related: Average Patching Time for SCADA Flaws Is 150 Days

Related Content

ICS/OT

UK’s NCSC releases security guidance for OT organizations considering migrating their SCADA solutions to the cloud.

ICS/OT

In an age of increasing geopolitical tensions caused by actual wars, and the threat of Chinese action against Taiwan, OT is a target that...

ICS/OT

SecurityWeek interviews Del Rodillas, Senior Director of Product Management at Palo Alto Networks, about the integration of IT and OT in the ICS threat landscape.

ICS/OT

Seven vulnerabilities found in Rapid SCADA could be exploited to gain access to sensitive industrial systems, but they remain unpatched.

ICS/OT

The Municipal Water Authority of Aliquippa was just one of multiple organizations breached in the U.S. by Iran-linked "Cyber Av3ngers" hackers

ICS/OT

Members of Congress asked the U.S. Justice Department to investigate how foreign hackers breached a water authority near Pittsburgh, prompting CISA to warn other...

ICS/OT

SecurityWeek’s 2023 ICS Cybersecurity Conference continues in Atlanta, as hundreds of industrial cybersecurity stakeholders gather for Day 2 of the annual industrial cybersecurity conference.

ICS/OT

Join SecurityWeek and TXOne Networks for this webinar as we expose common misconceptions surrounding the security of Operational Technology (OT) and dive into the...

Copyright © 2024 SecurityWeek ®, a Wired Business Media Publication. All Rights Reserved.

Exit mobile version