ICS/OT

AVEVA Patches Critical Flaws in HMI/SCADA Tools Following Schneider Merger

UK-based industrial software company AVEVA has patched two critical remote code execution vulnerabilities discovered by researchers in its InTouch and InduSoft development tools.

<p><strong><span><span>UK-based industrial software company AVEVA has patched two critical remote code execution vulnerabilities discovered by researchers in its InTouch and InduSoft development tools.</span></span></strong></p>

UK-based industrial software company AVEVA has patched two critical remote code execution vulnerabilities discovered by researchers in its InTouch and InduSoft development tools.

AVEVA merged with Schneider Electric earlier this year and took over the France-based industrial giant’s Avantis and Wonderware brands. The Wonderware portfolio includes the InduSoft Web Studio and InTouch Machine Edition HMI/SCADA software.

George Lashenko, a researcher with industrial cybersecurity firm CyberX, discovered that some versions of InTouch 2014 and 2017 are affected by a critical stack-based buffer overflow vulnerability. The flaw is tracked as CVE-2018-10628 and it has been assigned a CVSS score of 9.8.

“InTouch provides the capability for an HMI client to read and write tags defined in a view. A remote unauthenticated user could send a carefully crafted packet to exploit a stack-based buffer overflow vulnerability with potential for code to be executed while performing a tag-write operation on a locale that does not use a dot floating point separator. The code would be executed under the privileges of the InTouch View process and could lead to a compromise of the InTouch HMI,” AVEVA wrote in its advisory.

David Atch, VP of research at CyberX, told SecurityWeek that the vulnerability can be exploited remotely from the Internet if the targeted system is exposed to the Web. The attacker can take control of the HMI by directly sending it specially crafted packets, but the attack can also involve a piece of malware designed to send the malicious packets to the HMI.

“This provides the attacker with full control of the ICS process, enabling them to manipulate process parameters and potentially cause destructive actions like allowing pressure or temperature in a mixing tank to rise above acceptable levels,” Atch explained.

AVEVA released InTouch 2017 Update 2 HF-17_2 /CR149706 and InTouch 2014 R2 SP1 HF-11_1_SP1 /CR149705 on July 13 to patch the vulnerability.

Register for SecurityWeek’s 2018 ICS Cyber Security Conference

Separately, researchers at Tenable discovered another critical remote code execution vulnerability. The security hole, tracked as CVE-2018-10620 with a CVSS score of 9.8, impacts both InTouch Machine Edition and InduSoft Web Studio.

Advertisement. Scroll to continue reading.

“InduSoft Web Studio and InTouch Machine Edition provide the capability for an HMI client to read, write tags and monitor alarms and events. A remote user could send a carefully crafted packet to exploit a stack-based buffer overflow vulnerability during tag, alarm, or event related actions such as read and write, with potential for code to be executed. The code would be executed under the privileges of the Indusoft Web Studio or InTouch Machine Edition runtime and could lead to a compromise of the InduSoft Web Studio or InTouch Machine Edition server machine,” AVEVA said in its advisory.

The company patched the flaw on July 13 with the release of Hotfix 81.1.00.08 for each of the impacted products.

“These vulnerabilities leave InduSoft Web Studio or InTouch Machine Edition server machines vulnerable to an unauthenticated remote attacker who could leverage them to execute arbitrary code, potentially leading to full system compromise. In turn, these machines could allow an attacker to move laterally within a network. Connected HMI clients and OT devices can also be exposed to attacks,” Tenable said in a blog post, which includes technical details and a PoC exploit.

The flaw is similar to one disclosed by Tenable in early May, but it’s triggered via a different command.

Related: Schneider Electric Patches Critical Flaw in HMI Products

Related Content

ICS/OT

UK’s NCSC releases security guidance for OT organizations considering migrating their SCADA solutions to the cloud.

ICS/OT

In an age of increasing geopolitical tensions caused by actual wars, and the threat of Chinese action against Taiwan, OT is a target that...

ICS/OT

SecurityWeek interviews Del Rodillas, Senior Director of Product Management at Palo Alto Networks, about the integration of IT and OT in the ICS threat landscape.

ICS/OT

Seven vulnerabilities found in Rapid SCADA could be exploited to gain access to sensitive industrial systems, but they remain unpatched.

ICS/OT

The Municipal Water Authority of Aliquippa was just one of multiple organizations breached in the U.S. by Iran-linked "Cyber Av3ngers" hackers

ICS/OT

Members of Congress asked the U.S. Justice Department to investigate how foreign hackers breached a water authority near Pittsburgh, prompting CISA to warn other...

ICS/OT

SecurityWeek’s 2023 ICS Cybersecurity Conference continues in Atlanta, as hundreds of industrial cybersecurity stakeholders gather for Day 2 of the annual industrial cybersecurity conference.

ICS/OT

Join SecurityWeek and TXOne Networks for this webinar as we expose common misconceptions surrounding the security of Operational Technology (OT) and dive into the...

Copyright © 2024 SecurityWeek ®, a Wired Business Media Publication. All Rights Reserved.

Exit mobile version