9 Vulnerabilities Patched in SEL Power System Management Products 

Nine vulnerabilities patched in SEL electric power management products, adding to the 19 other flaws fixed earlier this year.

Nine vulnerabilities patched in SEL electric power management products, adding to the 19 other flaws fixed earlier this year.

Nine vulnerabilities, including potentially serious flaws, were patched recently in a couple of electric power management products made by Schweitzer Engineering Laboratories (SEL).

SEL is a US-based company that provides a wide range of products and services for the electric power sector, including control systems, generator and transmission protection, and distribution automation.

Researchers at industrial cybersecurity firm Nozomi Networks have analyzed the company’s SEL-5030 acSELerator QuickSet and SEL-5037 Grid Configurator, software products designed to allow engineers and technicians to configure and manage devices for power system protection, control, metering and monitoring, and to create and deploy settings for SEL power system devices.

Nozomi researchers discovered a total of nine vulnerabilities, including four that have been assigned a ‘high severity’ rating — the remaining five are ‘medium severity’.

The most severe, according to Nozomi, is CVE-2023-31171, which allows arbitrary code execution on the engineering workstation running the SEL software by getting the targeted user to import a device configuration from a specially crafted file. The flaw can be chained with CVE-2023-31175, which allows an attacker to escalate privileges. 

A malicious insider or an external threat actor (via social engineering) could exploit the vulnerabilities to steal sensitive data, for surveillance or manipulation of the device’s logic, and for lateral movement inside the victim’s network. 

Another serious issue can allow arbitrary command execution and changing a device’s configuration, either by getting the targeted user to click on a link, or by setting up a watering hole that the victim is likely to visit. 

“The native functionality to clear the terminal history could allow an attacker to cover up and erase their activities, making it more difficult for a target victim to spot any suspicious activity that may have happened in the background on their systems,” Nozomi warned.

SEL has been notified and it has released software updates that should patch these vulnerabilities.

Advertisement. Scroll to continue reading.

This is not the first time Nozomi has found vulnerabilities in SEL products. In May, the company reported identifying 19 security holes in SEL computing platforms running the vendor’s Realtime Automation Controller (RTAC) suite. 

“Worst case scenario, by chaining some of these vulnerabilities and performing a multi-step attack, an unauthenticated remote attacker could alter the core functionality of the device, allowing them to tamper with the information shown to operators or the configuration of the device itself,” Nozomi said at the time. “Additionally, access to all other systems protected by the same credentials could be acquired, allowing them to easily move laterally in the power infrastructure.”

Learn More at SecurityWeek’s ICS Cyber Security Conference
The leading global conference series for Operations, Control Systems and OT/IT Security professionals to connect on SCADA, DCS PLC and field controller cybersecurity.

October 23-26, 2023 | Atlanta
www.icscybersecurityconference.com

Related: Power Management Product Flaws Can Expose Data Centers to Damaging Attacks, Spying

Related: Power Grid Protection Firm SEL Patches Severe Software Flaws

Related: Exploited Solar Power Product Vulnerability Could Expose Energy Organizations to Attacks

Related: Australian Energy Software Firm Energy One Hit by Cyberattack

Related Content

ICS/OT

Government agencies are sharing recommendations following attacks claimed by pro-Russian hacktivists on ICS/OT systems.

ICS/OT

An analysis conducted by Honeywell shows that much of the USB-borne malware targeting industrial organizations can still cause OT disruption.

ICS/OT

Palo Alto Networks firewall vulnerability CVE-2024-3400, exploited as a zero-day, impacts a Siemens industrial product.

Nation-State

Mandiant summarizes some of the latest operations of Russia’s notorious Sandworm group, which it now tracks as APT44.

ICS/OT

In the past week Rockwell Automation addressed 10 vulnerabilities found in its FactoryTalk, PowerFlex and Arena Simulation products.

Malware & Threats

A suspicious NuGet package likely targets developers working with technology from Chinese firm Bozhon.

ICS/OT

UK’s NCSC releases security guidance for OT organizations considering migrating their SCADA solutions to the cloud.

ICS/OT

Siemens and Schneider Electric publish March 2024 Patch Tuesday advisories to inform customers about over 200 vulnerabilities.

Copyright © 2024 SecurityWeek ®, a Wired Business Media Publication. All Rights Reserved.

Exit mobile version